  Test procedure


  Sample Mounting


  Cables, Connectors


  Net and Sockets


  Device Activation


  Radiation Control


  Customs, Shipment


  Measurement Rooms


  Accommodation, Hotels


  Restaurants, Meals


  Map of PSI


  Map of Surroundings


 

 

  Beam Order


  Proton Tests 


  Electron Tests


  Some Essentials


  Useful Links


  Annual Reports




     

Google


WWW psi.ch


Updated:
23.03.2005
E-Mail: anita.vanloon@psi.ch

Printer Friendly Printout without Logo or Navigation Elements available here... just click and print

PSI Server Side Include SSI Information - to remove, set SSIINFO to execute with No in your /ssi/projectvariables.shtml

 

 


Essential Information for PIF Users

Registration and Arrival

Before arriving to PSI, please register as a user at https://duo.psi.ch.
You will find all necessary information in there. You will also be able to complete
the safety course as well as apply for your personal dosimeter and the entry card.
Both are required during your stay at PSI.

Experimental Procedure

Please provide us enough information for optimal planning of the whole
test. Data such as size of your active component area, number of samples
under test at the same time is very important for preparation of the proton
beam, collimators and shielding. This with the total number of components 
to be tested, required energies and doses allows to prepare the most optimal  
test procedure and minimize the required beam time. 

Sample Mounting

Please consider making use of the standard sample holder. It allows for
fast and easy mounting of your device (board, plate, chip etc.) on the beam
and setting its position. Don't hesitate to contact us if you need any assistance.

Cable Connections

The length of cables between test area and control barrack equals to ca. 30 m. 
User can either bring its own cables or use some of existing cables for their 
connections. Typically we provide some BNC and HV cables as well as RS232 
D25 and RJ49 twisted pair connections. 
There is also a possibility to remotely control user's PC located in the test site 
from the control barrack using Monitor/Mouse/Keyboard extender or another 
PC with suitable software installed (PCanywhere or VNC).

Net Voltages and Sockets/Plugs

Nominal parameters are 220 V, 50 Hz with Swiss type of plugs and sockets. 
Please inform us in advance if we should provide interfaces between Swiss 
and other 'European'  types of sockets. It will also be helpful to bring socket-
boards with yourself in order to plug your devices. 

Device Activation

It is natural that all materials exposed to protons will be activated and
for certain time cannot be taken out of the radiation controlled area. 
You can help to shorten the storing and activity decay period you by 
optimizing your test setup:

  • minimize the irradiated area of the device under test 
    e.g. use masks and collimators that can be de-attached from rest. 
  • expose to protons as little of the material bulk as possible 
    e.g. leave the space behind the tested device empty. 
  • Use low Z materials whenever possible 
    e.g. take plexiglas instead of Aluminum
     

Radiation Control After Test

Proton exposed devices must be controlled by PSI Health Physicists after 
completion of the test. Without it, no items are allowed to be removed outside
the radiation zone. Health Physicists are available during normal working hours
from Monday to Friday (8:00 to 17:00).

Shipment and Customs

Please look at How to order beam time for information about shipment and customs.

Measurement Rooms and Areas

Telephone number extensions:

Barrack 16 (PIF at PROSCAN) - 5386
Test area (PIF at PROSCAN) -